Filters Geyser Prestige are some of the most popular water purification systems for vehicles, especially among campervan, van and SUV owners. They provide protection against bacteria, heavy metals and mechanical impurities, which is critical when using water from untested sources. However incorrect connection may negate the benefits of the filter or even damage the vehicle's water supply.
In this article we will look at official connection diagrams for models Geyser Prestige 2 and Geyser Prestige PM, we will consider the necessary tools, typical mistakes and give recommendations for maintenance. The instructions are suitable for self-installation without the involvement of specialists, but require attention to detail.
If you plan to use the filter not only for drinking water, but also for showering or washing dishes, please note: the connection diagram will be different. We will separately dwell on the nuances for different operating scenarios.
1. Equipment and technical characteristics of Geyser Prestige filters
Before installation, check that the box with the filter contains all the necessary elements. Standard equipment Geyser Prestige 2 includes:
- ๐ง Main filter body with fastenings
- ๐ Replaceable cartridge (usually Aragon 2 or Barrier Pro)
- ๐ High pressure hoses (2 pcs., length 1โ1.5 m)
- ๐ Connection fittings (straight and angled)
- ๐ Product passport with warranty card
- ๐จ Fastening clamps (4 pcs.)
Technical parameters that are important to consider when connecting:
| Parameter | Geyser Prestige 2 | Geyser Prestige PM |
|---|---|---|
| Performance | 2.5 l/min | 1.8 l/min |
| Working pressure | 0.5โ6 atm | 0.3โ4 atm |
| Water temperature | +5โฆ+40ยฐC | +5โฆ+35ยฐC |
| Cartridge life | up to 10,000 l | up to 7,000 l |
| Weight (without water) | 1.8 kg | 1.5 kg |
Important: if the pressure in your system exceeds 6 atm (for example, in some campers with pumping stations), be sure to install pressure reducer in front of the filter. Otherwise, the cartridge membrane may break.
โ ๏ธ Attention! Cartridges Aragon 2 sensitive to chlorine. If you refill from a city water supply, use an activated carbon pre-filter or flush the system for 5-10 minutes before first use.
2. Tools and materials for connection
For filter installation Geyser Prestige you will need:
- ๐จ Adjustable wrench (for tightening fittings)
- ๐ช Knife or pipe cutter (for cutting hoses)
- ๐ Tape measure or ruler (for measuring the length of hoses)
- ๐งฐ FUM tape or plumbing flax (for sealing threaded connections)
- ๐ Voltage tester (if you connect to an electric pump)
- ๐งด Silicone grease (for O-rings)
Additionally you may need:
- ๐ Check valve (if not included in the kit)
- ๐ง Tee for inserting into the water main
- ๐ฆ Fastening clips for fixing hoses
Critical detail: If you are connecting the filter to plastic pipes (such as in a camper), use only compression fittings โ they do not damage pipes when tightened, unlike threaded ones.
3. Selecting an installation location: criteria and recommendations
Not only ease of use, but also the service life of the filter depends on the installation location. Optimal options:
- ๐ Under the sink in the camper - the most common solution. The filter is protected from mechanical damage, and the hoses can be hidden in a cabinet.
- ๐ง In the technical compartment - if there is access to water pipes and enough space for maintenance.
- ๐๏ธ On the outside panel of the van - convenient for quickly replacing the cartridge, but requires protection from frost and direct sunlight.
What to avoid:
- ๐ฅ Installations near heating devices (risk of cartridge overheating).
- ๐ง Installation in places where splashes or condensation are possible (the filter housing is not sealed!).
- ๐ Placed next to electrical wiring (even if the filter is not electric).
If you set the filter to winter conditions, provide the possibility of draining water or use a model with antifreeze cartridge (for example, Geyser Prestige Arctic).
Before finally attaching the filter, fill it with water and check for leaks. This is easier to do on weight than after fixing it on the wall.
4. Step-by-step diagram for connecting the Geyser Prestige filter
Let's consider a universal connection diagram for most automotive systems. If your camper or van has specific wiring, adaptations may be required.
Step 1: Shut off the water and prepare the pipes
Turn off the water supply to the system (close the tap or disconnect the pump). If the filter is installed in an existing pipeline, cut the pipe at the insertion point, leaving a margin of 5โ10 cm for maneuver.
Step 2: Installing the Tee
Insertion into the pipe is carried out using tee. For plastic pipes use soldering machine, for metal ones - threaded tee with FUM tape. Example of a cut-in path:
Main line โ Tee โ Hose to filter (inlet) โ Filter โ Hose from filter (outlet) โ Tap
Step 3: Connecting the Hoses
Connect the hoses to the filter using compression fittings. Important: the arrow on the filter housing should indicate the direction of water flow (from inlet to outlet). Tighten the fittings with an adjustable wrench, but do not use excessive force - the plastic may burst.
Step 4: Attaching the Filter
Secure the filter housing to the wall or panel using the supplied clamps. Leave a gap of 2โ3 cm to remove the cartridge. If the filter hangs on the hoses, install additional clips for fixation.
Step 5: Leak Test
Turn on the water and inspect all connections. If leaks are found:
- Tighten the fittings (but don't overdo it!).
- Check the O-rings - lubricate with silicone if necessary.
- If there is a leak at the insertion point of the tee, turn off the water and seal the connection with FUM tape.
โ๏ธ Check before first launch
5. Connection to an electric pump (for models with a pump)
Some modifications Geyser Prestige (for example, Prestige PM-2E) are equipped with a built-in pump to increase pressure. In this case, you will need to connect to the vehicle's on-board network.
Connection diagram:
- Connect red wire pump to
+12V(via 5A fuse). - Black wire ground to the body or the negative terminal of the battery.
- Install switch into the positive wire for manual control.
โ ๏ธ Attention! Do not connect the pump directly to the cigarette lighter - this may cause the wiring to overheat. Use a separate relay line or fuse box.
To automatically turn on the pump when the tap is opened, you can set pressure switch (for example, RDM-5). Relay connection diagram:
Pump โ Relay (pins 85, 86) โ Pressure (pin 87) โ Supply line
What to do if the pump does not pump water?
1. Check the fuse - it may burn out during a power surge.
2. Make sure that the cartridge is not clogged (try blowing out the inlet hose).
3. Inspect the pump impeller - sometimes it is blocked by sand or rust.
4. Measure the voltage at the pump terminals - it should be at least 11.5V.
6. Typical connection mistakes and how to avoid them
Even experienced car owners sometimes make mistakes that lead to filter failure or leaks. Here are the most common:
| Error | Consequences | How to fix |
|---|---|---|
| Failure to comply with flow direction | The cartridge quickly becomes clogged, the water is not purified | Turn the filter over according to the arrow on the housing |
| Using incompatible fittings | Leaks, failure of pressure hoses | Replace with fittings from the kit or similar in diameter |
| No check valve | The water drains back into the tank, the pump runs idle | Install a valve at the outlet of the filter |
| Re-upholstery of plastic fittings | Cracks in the body, leaks | Tighten by hand + 1/4 turn with wrench |
Another common problem is water freezing in the filter in winter. If you operate your car in the cold season:
- ๐๏ธ Drain the water from the system after each trip.
- ๐ฅ Use a heating cable for hoses (power no more than 10 W/m).
- ๐ง Replace water with non-freezing liquid (for example, Antifrogen N).
If the filter is not used for more than 2 weeks, wash it with a solution of citric acid (1 tablespoon per 1 liter of water) - this will prevent the development of bacteria in the cartridge.
7. Cartridge maintenance and replacement
The service life of the cartridge depends on the quality of the water and the intensity of use. On average, replacement is required every 6โ12 months or after filtering 5,000โ10,000 liters (see technical specifications table above).
Signs that it is time to change the cartridge:
- ๐ง Reducing water pressure at the outlet.
- ๐คข The appearance of an unpleasant taste or smell.
- ๐ Visible dirt on the outlet hose (rust, black particles).
Step-by-step cartridge replacement:
- Turn off the water and release the pressure by opening the tap.
- Click on the button
PUSHon the filter housing and remove the flask. - Remove the old cartridge and rinse the flask with warm water (no detergents!).
- Install the new cartridge, making sure the O-ring is in place.
- Close the flask until it clicks and check for leaks.
After replacing the cartridge, the first 5โ10 liters of water drain - this is necessary to flush the system from carbon dust (if a cartridge with activated carbon is used).
FAQ: Frequently asked questions about connecting Geyser Prestige
Is it possible to connect the Geyser Prestige filter to the city water supply?
Yes, but only if the network pressure does not exceed 6 atm. Otherwise, install the gearbox. A coarse pre-filter is also recommended (e.g. Geyser 1PF) to protect the cartridge from rust and sand.
How often should the filter be washed if it is rarely used?
For rare use (once every 1โ2 months), flush the system every 3 months, passing 10โ15 liters of water through the filter. This will prevent stagnation and bacterial growth. If the filter has been idle for more than 6 months, replace the cartridge regardless of its condition.
Is it possible to use a salt water filter (for example, on a yacht)?
No, models Geyser Prestige not intended for desalination. For salt water you need reverse osmosis or specialized membrane filters (for example, Geyser Opal).
What should I do if, after connecting, the water flows in a thin stream?
The reasons may be the following:
- The cartridge is clogged (replacement is required).
- Inlet pressure too low (install pump).
- The outlet hose is pinched (check the route).
- The check valve is faulty (replace it).
Start by checking the pressure with a pressure gauge.
Is it possible to connect a filter to a gas water heater?
No, Geyser Prestige not certified for use in hot water systems. The maximum inlet water temperature is +40ยฐC. For geysers, use specialized filters (for example, Aquaphor Viking).